Refine

DNC Workwear FR HRC2 Hi Vis 1/2 Zip Day/Night Jumper (3424)

SKU: 3424(DNC)
Manufacturer: DNC Workwear
  • Size chart
*
*
$151.47 incl GST
or 4 interest free payments of $37.87 with Afterpay logo Learn more

DNC Workwear FR HRC2 Hi Vis 1/2 Zip Day/Night Jumper (3424)

HRC2 - ATPV: 8+cal/cm2. FR flap at centre front placket with SBS 5# Vislon zipper, LHS chest pocket with FR flap and touch tape closure. FR elastic cuffs and waist band. Standard Hoop Pattern "ANS UL-209 FR" Segmented FR Reflective Tape (50 Washes) on body and sleeves. 2 tone front and back.

Attributes
  • SUN Protection UPF 50+ - DNC garments are tested for UPF (ultraviolet protection factor) in accordance with AS/NZS4399:1996. The level of protection varies depending on the fabric and colour of the garment. 15+ good protection, 30+ / 35+ very good protection, 40+ / 50+ excellent protection
  • Hi Vis - DNC Hi Vis fabric and reflective tape are manufactured to comply with the New Hi Vis standard Class F (AS/NZS1906.4:2010).
  • HiVis D/N Fabric & Design - DNC HiVis garments are manufactured to comply with New Hi Vis standard Class F AS/NZS1906.4:2010, Class DIN, AS/NZS 4602.1:2011 to meet the requirements of Hi­Vis Safety standards HiVis Fabric & Design of garments, for day and night use.
  • Carbon grid Anti-static - The latest technology is used in the production of DNC Flame retardant + Carbon grid Anti-static 98% Polyester/PU, 2% Carbon, breathable waterproof fabric rain jacket, vest & pants. DNC cotton garments containing no metal buttons/zip are also classified under Anti-static garments. (Complies with EN ISO 14116:2008 for FR & BS EN1149-5:2008 for Anti-static).
  • PPE2 ATPV: 8+ Cal/cm² - NFPA 70E / ASTM F1959 - Electrical Safety in the Workplace - Personal Protective Equipment (PPE) Category 2, PPE2(HRC2) min ATPV 8 Cal/cm2. ISO 14116:2015 (FR) - prescribes the performance criteria for material assemblies and protective clothing to minimise the risk of clothing igniting when exposed to small flames during short and intermittent contact, thereby minimising the potential hazard..
  • ISO 11612:2015 (FR) - This clothing aims to shield the wearer from splashes of molten metal, brief exposure to flames, radiant heat from electric arcs, and hazards related to welding and similar activities. It also provides limited protection against electrical shock during short-term contact with live electrical conductors of around 100 volts (Note: Sweat, soiling, or other contaminants can impact the level of protection). PPE2 ATPV: 8+ caI/cm2 - Personal Protective Equipment (PPE) is an important line of defense in arc flash safety. NFPA 70E:2018 standard uses four categories of PPE, with each category including the minimum Arc Rating value for the required PPE. PPE 1: 4 cal/cm², PPE 2: 8 cal/cm², PPE 3: 25 cal/cm², PPE 4: 40 cal/cm²

DNC Workwear FR HRC2 Hi Vis 1/2 Zip Day/Night Jumper (3424)

HRC2 - ATPV: 8+cal/cm2. FR flap at centre front placket with SBS 5# Vislon zipper, LHS chest pocket with FR flap and touch tape closure. FR elastic cuffs and waist band. Standard Hoop Pattern "ANS UL-209 FR" Segmented FR Reflective Tape (50 Washes) on body and sleeves. 2 tone front and back.

Attributes
  • SUN Protection UPF 50+ - DNC garments are tested for UPF (ultraviolet protection factor) in accordance with AS/NZS4399:1996. The level of protection varies depending on the fabric and colour of the garment. 15+ good protection, 30+ / 35+ very good protection, 40+ / 50+ excellent protection
  • Hi Vis - DNC Hi Vis fabric and reflective tape are manufactured to comply with the New Hi Vis standard Class F (AS/NZS1906.4:2010).
  • HiVis D/N Fabric & Design - DNC HiVis garments are manufactured to comply with New Hi Vis standard Class F AS/NZS1906.4:2010, Class DIN, AS/NZS 4602.1:2011 to meet the requirements of Hi­Vis Safety standards HiVis Fabric & Design of garments, for day and night use.
  • Carbon grid Anti-static - The latest technology is used in the production of DNC Flame retardant + Carbon grid Anti-static 98% Polyester/PU, 2% Carbon, breathable waterproof fabric rain jacket, vest & pants. DNC cotton garments containing no metal buttons/zip are also classified under Anti-static garments. (Complies with EN ISO 14116:2008 for FR & BS EN1149-5:2008 for Anti-static).
  • PPE2 ATPV: 8+ Cal/cm² - NFPA 70E / ASTM F1959 - Electrical Safety in the Workplace - Personal Protective Equipment (PPE) Category 2, PPE2(HRC2) min ATPV 8 Cal/cm2. ISO 14116:2015 (FR) - prescribes the performance criteria for material assemblies and protective clothing to minimise the risk of clothing igniting when exposed to small flames during short and intermittent contact, thereby minimising the potential hazard..
  • ISO 11612:2015 (FR) - This clothing aims to shield the wearer from splashes of molten metal, brief exposure to flames, radiant heat from electric arcs, and hazards related to welding and similar activities. It also provides limited protection against electrical shock during short-term contact with live electrical conductors of around 100 volts (Note: Sweat, soiling, or other contaminants can impact the level of protection). PPE2 ATPV: 8+ caI/cm2 - Personal Protective Equipment (PPE) is an important line of defense in arc flash safety. NFPA 70E:2018 standard uses four categories of PPE, with each category including the minimum Arc Rating value for the required PPE. PPE 1: 4 cal/cm², PPE 2: 8 cal/cm², PPE 3: 25 cal/cm², PPE 4: 40 cal/cm²
Products specifications
Fabric 280 GSM 60% Modacrylic, 39% Cotton and 1% Carbon anti-static super soft Fleece
Material Flame Retardant